your wishlist is empty

M2XCH-FFR 0,6/1 kV (NOFI) (SC)


Description

Applicable as fixed installed power cables in various electromechanical and electronic appliances of marine vehicles where a sustainable connection during a fire is required. The overall screen minimizes environmental electromagnetic interference. Usable at all conditions in marine environment such as dry, wet or oily applications, where electromagnetic protection is also required. Even at direct contact with fire the cable will sustain the connection for 180 min.. That means that the necessary appliances (fire alarm- and extinguishing-systems, water pumps, lighting, communication-, radio-, control-systems etc.) will work uninterrupted during a fire. Due to its halogen-free and flame-retardant features as well as the low-smoke density feature it will neither create corrosive gases nor obstruct visibility, it prevents the spread of fire. Thus the cables are able to protect human life and equipment during a fire.




Technical attributes
Standards DIN 89158, IEC 60092/353, IEC 60092/350-351-359, IEC 60332/1, IEC60332/3 Cat A, IEC 60331, IEC 60754/1-2, IEC 61034/1-2 (DIN EN 50268/1-2)
Conductor material annealed Electrolytic-Cu, bare
Conductor type flexible
Conductor standard IEC 60228
Conductor category 5
1. Seperating layer Mica tape
Core structure sector conductor
Core colours 2-cores: blue/brown; 3-cores: brown/black/grey; 7-cores: white, number-coded, without GN/YE-protection conductor
Core insulation XLPE
2. Seperating layer separating foil, ≥ 25 mm² with filler
Screening Electrolytic-Cu-braiding
Outer sheath Thermoplastic Polyolefin (TPO) Mischungstyp: HM4/SHF1 nach IEC 60092-359 (SHF2 on request)
Outer sheath colour orange
Temperature range min., mobile operation -40 °C
Temperature range max., mobile operation +90 °C
Nominal voltage Uo/U 0,6/1 kV kV
Test voltage 3,5 kV
Minimum bending radius, fixed installation 8 x cable cross-section


undefined

Power cable, flame-retardant DNV | BV | ABS | Class NK | RINA

On request :with filler "FI", class 2, further cross-sections/outer jacket colours

● halogen-free IEC 60754/1-2

● flame-retardant IEC 60332/1, IEC 60332/3 Cat A

● fire-resistant IEC 60331

● oil-resistant

● smoke density IEC 61034/1-2 (DIN EN 50268/1-2)




Product table

PNr. product name remember
 Weight ca. [kg]Cu-weight [kg]External dimensions ca. [mm]Outer-Ø ca. [mm]Outer sheath colour 
04094001M2XCH-FFR (NOFI) 0,6/1kV 3x35 or flex Kl.5 SC remember
 1310,001183,50Kl, 523,60orange 
04094005M2XCH-FFR (NOFI) 0,6/1kV 4x35 or flex Kl.5 SC remember
 1720,001539,10Kl, 527,60orange 
04094002M2XCH-FFR (NOFI) 0,6/1kV 3x50 or flex Kl.5 SC remember
 1800,001638,70Kl, 528,00orange 
04094006M2XCH-FFR (NOFI) 0,6/1kV 4x50 or flex Kl.5 SC remember
 2330,002145,70Kl, 531,30orange 
04094003M2XCH-FFR (NOFI) 0,6/1kV 3x70 or flex Kl.5 SC remember
 2415,002254,30Kl, 531,50orange 
04094004M2XCH-FFR (NOFI) 0,6/1kV 3x95 or flex Kl.5 SC remember
 3075,003095,90Kl, 534,00orange 
04094008M2XCH-FFR (NOFI) 0,6/1kV 4x95 or flex Kl.5 SC remember
 4140,004049,20Kl, 540,00orange 
04094007M2XCH-FFR (NOFI) 0,6/1kV 3x120or flex Kl.5 SC remember
 4035,003910,60Kl, 540,20orange 
default message