FMGCH
Description
Medium Voltage power distribution, electric power transport between the engine room generator andelectrical machines. Used as fixed installation cables in various electromechanical and electronic equipments.Due to its’ overall screen the electromagnetic interference is minimized.
Technical attributes
| Standards | IEC 60228, DIN 89159, IEC 60092/375 - 376, IEC 60092 /350-351-359, IEC 60332 /1, IEC 60332 / 3 Cat A, IEC 60754 / 1 - 2, IEC 61034 / 1-2 ( DIN EN 50268/1-2) |
| Conductor material | Electrolytic annealed flexible Cu-bare wires |
| Conductor type | flexible |
| Conductor standard | IEC 60228 |
| Conductor category | 2 (5 and/or tinned on request) |
| Core insulation | HEPR-compound, halogen-free |
| Core structure | Cores laid up in pair, pairs laid up concentrically |
| Screening | Electrolytic bare Cu-braiding (min. 90% coverage) |
| Outer sheath | Halogen-free, flame retardant, thermoplastic polyolefin based compound (HM4 / SHF1) |
| Outer sheath colour | black or grey |
| Temperature range min., mobile operation | -40 °C |
| Temperature range max., mobile operation | +90 °C |
| Nominal voltage Uo/U | 60/250 V |
| Test voltage | 1,5 kV |
| Minimum bending radius, fixed installation | 8 x cable cross-section |
Communication and telecommunication cable, flame-retardant, fully screened
● halogen-free IEC 60754/1-2
● flame-retardant IEC 60332/1, IEC 60332/3 Cat A
● oil-resistant
● smoke density IEC 61034/1-2 (DIN EN 50268/1-2)
Product table
| PNr. | product name | remember | |||
| Weight ca. [kg] | Cu-weight [kg] | Outer-Ø ca. [mm] | Outer sheath colour | ||
| 04054001 | FMGCH 24 x 2 x 0,75 bk | ||||
| 888,00 | 490,60 | 28,00 | black or grey | ||