your wishlist is empty

M2XCH-FFR 0,6/1 kV (NOFI)


Description

Applicable as fixed installed power cables in various electromechanical and electronic appliances of marine vehicles where a sustainable connection during a fire is required. The overall screen minimizes environmental electromagnetic interference. Usable at all conditions in marine environment such as dry, wet or oily applications, where electromagnetic protection is also required. Even at direct contact with fire the cable will sustain the connection for 180 min.. That means that the necessary appliances (fire alarm- and extinguishing-systems, water pumps, lighting, communication-, radio-, control-systems etc.) will work uninterrupted during a fire. Due to its halogen-free and flame-retardant features as well as the low-smoke density feature it will neither create corrosive gases nor obstruct visibility, it prevents the spread of fire. Thus the cables are able to protect human life and equipment during a fire.




Technical attributes
Standards DIN 89158, IEC 60092/353, IEC 60092/350-351-359, IEC 60332/1, IEC60332/3 Cat A, IEC 60331, IEC 60754/1-2, IEC 61034/1-2 (DIN EN 50268/1-2)
Conductor material annealed Electrolytic-Cu, bare
Conductor type flexible
Conductor standard IEC 60228
Conductor category 5
1. Seperating layer Mica tape
Core insulation XLPE
Core colours 2-cores: blue/brown; 3-cores: brown/black/grey; 7-cores: white, number-coded, without GN/YE-protection conductor
2. Seperating layer separating foil, ≥ 25 mm² with filler
Screening Electrolytic-Cu-braiding
Outer sheath Thermoplastic Polyolefin (TPO) compound: HM4/SHF1 acc. to IEC 60092-359
Outer sheath colour orange
Temperature range min., mobile operation -40 °C
Temperature range max., mobile operation +90 °C
Nominal voltage Uo/U 0,6/1 kV
Test voltage 3,5 kV
Minimum bending radius, fixed installation 8 x cable-Ø


undefined

Power cable, flame-retardant, screened

On request :with filler "FI", class 2, further cross-sections/outer jacket colours

● halogen-free IEC 60754/1-2

● flame-retardant IEC 60332/1, IEC 60332/3 Cat A

● fire-resistant IEC 60331

● oil-resistant

● smoke density IEC 61034/1-2 (DIN EN 50268/1-2)




Product table

PNr. product name remember
 Weight ca. [kg]Cu-weight [per_km]Outer-Ø ca. [mm]Outer sheath colour 
04048002M2XCH-FFR (NOFI) 0,6/1 kV 2 x 1,5 og flex Cl5 remember
 120,0072,509,70orange 
04048003M2XCH-FFR (NOFI) 0,6/1kV 3 x 1,5 og flex Cl.5 remember
 145,0087,8010,20orange 
04048006M2XCH-FFR (NOFI) 0,6/1kV 4 x 1,5 og flex Cl.5 remember
 178,00106,6011,30orange 
04048021M2XCH-FFR (NOFI) 0,6/1kV 5 x 1,5 og flex Cl.5 remember
 210,00127,4012,30orange 
04048004M2XCH-FFR (NOFI) 0,6/1 kV 7 x 1,5 og flex Cl.5 remember
 290,00190,6013,60orange 
04048024M2XCH-FFR(NOFI) 0,6/1kV 12 x 1,5 og flex Cl.5 remember
 446,00287,6017,80orange 
04048011M2XCH-FFR (NOFI) 0,6/1kV 2 x 2,5 og flex Cl.5 remember
 150,0095,9010,60orange 
04048005M2XCH-FFR (NOFI) 0,6/1 kV 3 x 2,5 og flex Cl5 remember
 190,00123,5011,40orange 
04048007M2XCH-FFR (NOFI) 0,6/1 kV 3 x 4 og flex Cl.5 remember
 245,00172,5012,60orange 
04048060M2XCH-FFR (NOFI) 0,6/1 kV 3 G 4 og flex Cl.5 remember
 245,00172,5012,60orange 
04048064M2XCH-FFR (NOFI) 0,6/1 kV 4 G 4 og flex Cl.5 remember
 340,00252,0014,4orange 
04048068M2XCH-FFR (NOFI) 0,6/1 kV 5 G 4 og flex Cl.5 remember
 405,00282,0015,60orange 
04048008M2XCH-FFR (NOFI) 0,6/1 kV 3 x 6 og flex Cl.5 remember
 345,00232,0014,30orange 
04048061M2XCH-FFR (NOFI) 0,6/1 kV 3 G 6 og flex Cl.5 remember
 345,00232,0014,30orange 
04048065M2XCH-FFR (NOFI) 0,6/1 kV 4 G 6 og flex Cl.5 remember
 42533515,6orange 
04048069M2XCH-FFR (NOFI) 0,6/1 kV 5 G 6 og flex Cl.5 remember
 518,00389,4017,20orange 
04048062M2XCH-FFR (NOFI) 0,6/1 kV 3 G 10 og flex Cl.5 remember
 504,00399,5016,80orange 
04048009M2XCH-FFR (NOFI) 0,6/1 kV 3 x 10 og flex Cl.5 remember
 504,00399,5016,80orange 
04048066M2XCH-FFR (NOFI) 0,6/1 kV 4 G 10 og flex Cl.5 remember
 625,00503,7018,40orange 
04048070M2XCH-FFR (NOFI) 0,6/1 kV 5 G 10 og flex Cl.5 remember
 770,00629,8020,40orange 
04048063M2XCH-FFR (NOFI) 0,6/1 kV 3 G 16 og flex Cl.5 remember
 710,00588,7019,00orange 
04048018M2XCH-FFR (NOFI) 0,6/1 kV 3 x 16 og flex Cl.5 remember
 710,00588,7019,00orange 
04048067M2XCH-FFR (NOFI) 0,6/1 kV 4 G 16 og flex Cl.5 remember
 880,00755,6021,00orange 
04048071M2XCH-FFR (NOFI) 0,6/1 kV 5 G 16 og flex Cl.5 remember
 1085,00929,7023,30orange 
default message